Difference between revisions of "Manuals:User manual"

From VectorMEP
Jump to navigation Jump to search
m
m
 
(10 intermediate revisions by the same user not shown)
Line 1: Line 1:
<div style="float:right">__TOC__</div>
+
<div style="float:right;">__TOC__</div>
 +
[[File:VectorMEP_User_Manual.pdf]]
 +
<br/>
 +
We are still converting our PDF manual to be included in this wiki. As long as you see this message and the reference above we advise to use the pdf instead of the content below.
 
== IFC Comptability ==
 
== IFC Comptability ==
 
All the available MEP components are able to be exported to the by Vectorworks supported
 
All the available MEP components are able to be exported to the by Vectorworks supported
Line 8: Line 11:
 
Contact us directly if you would like to have additional information transferred to the IFC tags by default.
 
Contact us directly if you would like to have additional information transferred to the IFC tags by default.
  
<syntaxhighlight lang="html">
 
 
IFC is an open standard, developed and maintained by buildingSMART International, for building data that permits information to be shared and maintained throughout the life cycle of the construction project: design, analysis, specification, fabrication, construction, and occupancy.
 
IFC is an open standard, developed and maintained by buildingSMART International, for building data that permits information to be shared and maintained throughout the life cycle of the construction project: design, analysis, specification, fabrication, construction, and occupancy.
</syntaxhighlight>
 
  
 
== Global Settings ==
 
== Global Settings ==
Using the "//MEP DISCIPLINE// - Settings" menu command, a dialog appears to manage
+
Using the "//MEP DISCIPLINE// - Settings" menu command, a dialog appears to manage global settings for that specific discipline.
 
 
global settings for that specific discipline.
 
  
 
Available disciplines:
 
Available disciplines:
Line 23: Line 22:
 
* Ducting
 
* Ducting
  
Most settings are saved into the active drawing. If you are familiar with Vectorworks
+
Most settings are saved into the active drawing. If you are familiar with Vectorworks templates this is ideal to setup defaults for future projects.
 
 
templates this is ideal to setup defaults for future projects.
 
 
 
General
 
  
 +
=== General ===
 
Depending on the category, different common settings will be available.
 
Depending on the category, different common settings will be available.
  
== Classification ==
+
=== Classification ===
Manage the classification system, create predefined family types to categorize and
+
Manage the classification system, create predefined family types to categorize and personalize your components.
 
 
personalize your components.
 
 
 
Calculation
 
 
 
An overview of the available sizing and calculation methods. These methods can be
 
 
 
extended by anyone using the SDK.
 
 
 
Materials
 
 
 
Manage available materials and dimensions. Dimensions are shown based on the active
 
  
document unit settings.
+
=== Calculation ===
 +
An overview of the available sizing and calculation methods. These methods can be extended by anyone using the SDK.
  
Once a dimension is added to a material you can set it to be used as width and/or height by
+
=== Materials ===
 +
Manage available materials and dimensions. Dimensions are shown based on the active document unit settings.
  
clicking the icons in the list browser.
+
Once a dimension is added to a material you can set it to be used as width and/or height by clicking the icons in the list browser.
  
 
Material settings are managed outside the document and are not part of a template.
 
Material settings are managed outside the document and are not part of a template.
  
Global Settings
+
=== Angles ===
 
 
19
 
 
 
Angles
 
 
 
 
Manage the available angles while using the MEP component tools.
 
Manage the available angles while using the MEP component tools.
  
Units
+
=== Units ===
 
+
For some of our parameters, custom unit implementations are available. Our custom unit parameters fully support worksheets and the irrigation tag, translating the saved value to be displayed in the unit settings of your choice.
For some of our parameters, custom unit implementations are available. Our custom unit
 
 
 
parameters fully support worksheets and the irrigation tag, translating the saved value to be
 
 
 
displayed in the unit settings of your choice.
 
  
 
Both the Imperial and Metric unit system are supported.
 
Both the Imperial and Metric unit system are supported.
  
Symbols
+
=== Symbols ===
 
+
MEP components have an optional hybrid/2D view. These symbols will be displayed for each component type to indicate special cases in 2D plan view. (E.g drop, rise...)
MEP components have an optional hybrid/2D view. These symbols will be displayed for
 
 
 
each component type to indicate special cases in 2D plan view. (E.g drop, rise...)
 
  
 
Optional, you can set the symbol to rotate and scale:
 
Optional, you can set the symbol to rotate and scale:
  
Rotating: This will rotate the symbol into the direction on the XY plane.
+
* Rotating: This will rotate the symbol into the direction on the XY plane.
 
+
* Scaling: This will scale the symbol to match the component size. The scale will be calculated based on the pipe size versus the width of an 360°arc in the symbol definition. For best performance reasons you should put all the symbol contents into a group, except for the arc. The arc can be given an invisible pen and fill if you'd like to hide it.
Scaling:This will scale the symbol to match the component size. The scale will be
 
 
 
calculated based on the pipe size versus the width of an 360°arc in the symbol
 
 
 
definition. For best performance reasons you should put all the symbol contents into a
 
 
 
group, except for the arc. The arc can be given an invisible pen and fill if you'd like to
 
 
 
hide it.
 
 
 
Insulation
 
  
 +
=== Insulation ===
 
Manage insulation and lining predefined types.
 
Manage insulation and lining predefined types.
  
Performance
+
=== Performance ===
 
 
 
Manage various settings with influence on performance:
 
Manage various settings with influence on performance:
  
Line 107: Line 69:
  
 
Segmentise "Straight Group Segments"
 
Segmentise "Straight Group Segments"
 
Global Settings
 
 
20
 
  
 
Straight Segment Groups will internally split into multiple Straight Segments based on
 
Straight Segment Groups will internally split into multiple Straight Segments based on
Line 122: Line 80:
 
Internally there will be 5 segments.
 
Internally there will be 5 segments.
  
Discipline specific settings
+
=== Discipline specific settings ===
 
 
Fluids
 
  
 +
==== Fluids ====
 
Manage fluids by temperature, viscosity and density to be used when predefining family
 
Manage fluids by temperature, viscosity and density to be used when predefining family
  
 
types.
 
types.
  
Underfloor heating
+
==== Underfloor heating ====
 
 
 
Manage reducing factors to be used with the underfloor heating object.
 
Manage reducing factors to be used with the underfloor heating object.
  
Load calculations
+
==== Load calculations ====
 
 
 
Manage common settings for electrical engineering, regarding power loads.
 
Manage common settings for electrical engineering, regarding power loads.
  
Global Settings
+
== Classification ==
 
 
21
 
 
 
Classification
 
 
 
 
VectorMEP provides a classification system to categories MEP components.
 
VectorMEP provides a classification system to categories MEP components.
  
Line 160: Line 110:
 
family type.
 
family type.
  
Creating a family type
+
=== Creating a family type ===
 
 
 
Family types can be managed in the Classification tab of the MEP settings dialog.
 
Family types can be managed in the Classification tab of the MEP settings dialog.
  
Piping
+
==== Piping ====
  
Classification
+
==== Electrical ====
 
 
22
 
 
 
Electrical
 
  
Classification
+
==== Ducting ====
 
 
23
 
 
 
Ducting
 
 
 
Classification
 
 
 
24
 
 
 
Assigning a family type
 
  
 +
=== Assigning a family type ===
 
Each MEP component can be directly assigned to a family type, taking over the
 
Each MEP component can be directly assigned to a family type, taking over the
  
 
predefined settings.
 
predefined settings.
  
Classification
+
== Connectors ==
 
 
25
 
 
 
Connectors
 
 
 
 
Connectors are logical entities that are the missing link between a symbol/object and a MEP
 
Connectors are logical entities that are the missing link between a symbol/object and a MEP
  
Line 204: Line 135:
 
and symbols to create smart responsive objects participating in MEP networks.
 
and symbols to create smart responsive objects participating in MEP networks.
  
Choosing the right Connector
+
=== Choosing the right Connector ===
 
 
 
Different type of connectors are available depending on the discipline:
 
Different type of connectors are available depending on the discipline:
  
Line 240: Line 170:
 
article.
 
article.
  
Adding connectors
+
=== Adding connectors ===
 
 
 
You can add connectors using the following methods:
 
You can add connectors using the following methods:
  
Line 258: Line 187:
 
as a button on the OIP to enter this group.
 
as a button on the OIP to enter this group.
  
Connector oriëntation
+
=== Connector oriëntation ===
 
 
 
While selecting a connector, the direction is highlighted. The connector should always point
 
While selecting a connector, the direction is highlighted. The connector should always point
  
Line 268: Line 196:
 
27
 
27
  
Pipe connectors
+
=== Connector types ===
  
 +
==== Pipe connectors ====
 
Pipe connectors are used for piping, pipe fittings, and other components that are meant for
 
Pipe connectors are used for piping, pipe fittings, and other components that are meant for
  
Line 320: Line 249:
 
Extrusion height
 
Extrusion height
  
Pipe connectors
+
==== Duct connectors ====
 
 
28
 
 
 
Duct connectors
 
 
 
 
Duct connectors are associated with ductwork, duct fittings, and other elements that are
 
Duct connectors are associated with ductwork, duct fittings, and other elements that are
  
Line 374: Line 298:
 
Extrusion height
 
Extrusion height
  
Duct connectors
+
==== Electrical connectors ====
 
 
29
 
 
 
Electrical connectors
 
 
 
 
Electrical connectors are used for any type of electrical connection, including power,
 
Electrical connectors are used for any type of electrical connection, including power,
  
Line 430: Line 349:
 
Extrusion height
 
Extrusion height
  
Electrical connectors
+
==== CableCarrier connectors ====
 
 
30
 
 
 
CableCarrier connectors
 
 
 
 
CableCarrier connectors are associated with CableCarriers, CableCarriers fittings, and
 
CableCarrier connectors are associated with CableCarriers, CableCarriers fittings, and
  
Line 470: Line 384:
 
31
 
31
  
Managing systems
+
== Managing systems ==
 
 
Use of systems
 
  
 +
=== Use of systems ===
 
When fixtures have connectors assigned, it is possible to create logic groups of fixtures by
 
When fixtures have connectors assigned, it is possible to create logic groups of fixtures by
  
Line 482: Line 395:
 
For mechanical engineering, systems are logic groups of components.
 
For mechanical engineering, systems are logic groups of components.
  
Creating systems
+
=== Creating systems ===
 
 
 
There are two ways of managing systems, by using the tools are menu available menu
 
There are two ways of managing systems, by using the tools are menu available menu
  
Line 498: Line 410:
 
used to activate the system manager tool as well.
 
used to activate the system manager tool as well.
  
Creating electrical systems
+
==== Creating electrical systems ====
  
Creating piping systems
+
==== Creating piping systems ====
  
Creating ducting systems
+
==== Creating ducting systems ====
  
Using the system manager tool
+
=== Using the system manager tool ===
 
 
Managing systems
 
 
 
32
 
  
 
When using the system manager tool, you can select an existing system, or start with a new
 
When using the system manager tool, you can select an existing system, or start with a new
Line 522: Line 430:
 
Electrical systems can also be assigned to a panel directly using the tool.
 
Electrical systems can also be assigned to a panel directly using the tool.
  
Managing systems
+
== Managing Insulation ==
 
 
33
 
 
 
Managing Insulation
 
 
 
 
MEP components can have insulation or lining attached.
 
MEP components can have insulation or lining attached.
  
Line 534: Line 437:
 
VectorMEP ribbon.
 
VectorMEP ribbon.
  
Insulation ranges
+
=== Insulation ranges ===
 
 
 
When creating insulation/lining materials in the MEP settings dialogs, predefined ranges can
 
When creating insulation/lining materials in the MEP settings dialogs, predefined ranges can
  
Line 548: Line 450:
 
updated accordingly.
 
updated accordingly.
  
Adding insulation/Lining
+
=== Adding insulation/Lining ===
 
 
Managing insulation
 
 
 
34
 
 
 
 
The dialog will suggest a thickness based on the available ranges. The specific range will be
 
The dialog will suggest a thickness based on the available ranges. The specific range will be
  
 
highlighted in the listbrowser below.
 
highlighted in the listbrowser below.
  
Managing insulation
+
== Sizing and Calculation Methods ==
 
 
35
 
 
 
Sizing and Calculation Methods
 
 
 
 
The "MEP Component sizing" menu command allows sizing of MEP components by
 
The "MEP Component sizing" menu command allows sizing of MEP components by
  
Line 580: Line 472:
 
any calculation.
 
any calculation.
  
Sizing methods
+
=== Sizing methods ===
 
 
Sizing and Calculation Methods
 
 
 
36
 
 
 
 
Sizing methods size MEP components based on the results of a calculation method, within
 
Sizing methods size MEP components based on the results of a calculation method, within
  
Line 606: Line 493:
 
parameters could be satisfied.
 
parameters could be satisfied.
  
Custom methods
+
=== Custom methods ===
 
+
Both the sizing and calculation methods can be customized by adding additional implementations using our API.
Sizing and Calculation Methods
 
 
 
37
 
 
 
Both the sizing and calculation methods can be customized by adding additional
 
 
 
implementations using our API.
 
 
 
Sizing and Calculation Methods
 
 
 
38
 
 
 
Working with MEP components
 
  
 +
== Working with MEP components ==
 
Each discipline contains two tools to create rigid and flexible MEP components.
 
Each discipline contains two tools to create rigid and flexible MEP components.
  
Line 630: Line 505:
 
Both the tools allow components to be drawn in all directions, including sloped parts.
 
Both the tools allow components to be drawn in all directions, including sloped parts.
  
Pipe Component tool
+
=== Pipe Component tool ===
 
 
 
The "Pipe Component" tool draws pipework in a project.
 
The "Pipe Component" tool draws pipework in a project.
  
Duct Component tool
+
=== Duct Component tool ===
 
 
 
The "Duct Component" tool draws ductwork in a project.
 
The "Duct Component" tool draws ductwork in a project.
  
Cable Carrier Component
+
=== Cable Carrier Component ===
 
 
 
The "Cable Carrier Component" tool draws cable carries in a project.
 
The "Cable Carrier Component" tool draws cable carries in a project.
  
Creating MEP components
+
=== Creating MEP components ===
 
 
Tool Modebar
 
 
 
Working with MEP components
 
 
 
39
 
  
 +
==== Tool Modebar ====
 
1. Horizontal outline. (left, center, right)
 
1. Horizontal outline. (left, center, right)
  
Line 662: Line 529:
 
6. Object properties.
 
6. Object properties.
  
Contextual menu
+
==== Contextual menu ====
 
 
 
The right click contextual menu contains the following custom actions:
 
The right click contextual menu contains the following custom actions:
  
Line 717: Line 583:
  
 
Material
 
Material
 
Working with MEP components
 
 
40
 
  
 
Shape
 
Shape
Line 734: Line 596:
 
Lock height
 
Lock height
  
Working with MEP components
+
=== Working with MEP Placeholders ===
 
 
41
 
 
 
Working with MEP Placeholders
 
 
 
 
Each discipline contains a tool to create placeholders. These are a simplified variation of
 
Each discipline contains a tool to create placeholders. These are a simplified variation of
  
Line 748: Line 605:
 
quickly.
 
quickly.
  
Pipe Placeholder tool
+
==== Pipe Placeholder tool ====
 
 
 
The "Pipe Component" tool draws pipework in a project.
 
The "Pipe Component" tool draws pipework in a project.
  
Duct Placeholder tool
+
==== Duct Placeholder tool ====
 
 
 
The "Duct Component" tool draws ductwork in a project.
 
The "Duct Component" tool draws ductwork in a project.
  
Cable Carrier Placeholder
+
==== Cable Carrier Placeholder ====
 
 
 
The "Cable Carrier Component" tool draws cable carries in a project.
 
The "Cable Carrier Component" tool draws cable carries in a project.
  
Creating MEP Placeholders
+
=== Creating MEP Placeholders ===
 
 
Tool Modebar
 
 
 
Working with MEP Placeholders
 
 
 
42
 
  
 +
==== Tool Modebar ====
 
1. Width/Diameter
 
1. Width/Diameter
  
Line 778: Line 627:
 
5. Object properties.
 
5. Object properties.
  
Contextual menu
+
==== Contextual menu ====
 
 
 
The right click contextual menu contains the following custom actions:
 
The right click contextual menu contains the following custom actions:
  
Line 835: Line 683:
  
 
Shape
 
Shape
 
Working with MEP Placeholders
 
 
43
 
  
 
Size
 
Size
Line 850: Line 694:
 
Lock height
 
Lock height
  
Working with MEP Placeholders
+
== Remodelling components ==
 
 
44
 
 
 
Remodelling components
 
 
 
 
Existing MEP components can be remodeled in various ways.
 
Existing MEP components can be remodeled in various ways.
  
Line 864: Line 703:
 
any component besides the Straight Segment (Group) and the Transition Segment.
 
any component besides the Straight Segment (Group) and the Transition Segment.
  
Straight Segment (Group)
+
=== Straight Segment (Group) ===
 
 
 
The OIP holds a parameter "Length". On setting a new value the segment will use the new
 
The OIP holds a parameter "Length". On setting a new value the segment will use the new
  
 
provided length.
 
provided length.
  
Elbow Segments
+
=== Elbow Segments ===
 
 
 
The OIP holds a parameter "Radius". On setting a new value the segment will use the new
 
The OIP holds a parameter "Radius". On setting a new value the segment will use the new
  
Line 880: Line 717:
 
modified as well to match the new situation.
 
modified as well to match the new situation.
  
Modifying the angle
+
==== Modifying the angle ====
 
 
Remodelling components
 
 
 
45
 
 
 
 
1. Select an elbow, click on the center CP (A).
 
1. Select an elbow, click on the center CP (A).
  
Line 894: Line 726:
 
3. Click to verify the new position.
 
3. Click to verify the new position.
  
Converting into a junction
+
==== Converting into a junction ====
 
 
 
1. Select an elbow, click on any outer CP (B).
 
1. Select an elbow, click on any outer CP (B).
  
 
2. Click on any outer CP (B) to switch between enabling legs.
 
2. Click on any outer CP (B) to switch between enabling legs.
  
Transition Segments
+
=== Transition Segments ===
 
 
 
The OIP holds a parameter "Taper angle" and "Taper length". On setting a new value the
 
The OIP holds a parameter "Taper angle" and "Taper length". On setting a new value the
  
 
segment will use the new provided angle or length.
 
segment will use the new provided angle or length.
 
Remodelling components
 
 
46
 
  
 
If the Object has adjacent connecting objects, this will only succeed if those objects can be
 
If the Object has adjacent connecting objects, this will only succeed if those objects can be
Line 914: Line 740:
 
modified as well.
 
modified as well.
  
Horizontal shift
+
==== Horizontal shift ====
 
 
 
Each transition has 3 controlpoints to control a horizontal shift. From the OIP you can set an
 
Each transition has 3 controlpoints to control a horizontal shift. From the OIP you can set an
  
Line 926: Line 751:
 
3. Click to verify the new position.
 
3. Click to verify the new position.
  
Junction Segments
+
=== Junction Segments ===
 
 
 
The OIP holds a parameter "Radius". On setting a new value the segment will use the new
 
The OIP holds a parameter "Radius". On setting a new value the segment will use the new
  
 
provided radius.
 
provided radius.
  
Removing junction legs
+
==== Removing junction legs ====
 
 
Remodelling components
 
 
 
47
 
 
 
 
1. Select a junction.
 
1. Select a junction.
  
 
2. Click on any outer CP (B) to remove and existing leg.
 
2. Click on any outer CP (B) to remove and existing leg.
  
Adding junction legs
+
==== Adding junction legs ====
 
 
 
You can add infinite legs to a junction. Each time you draw a segment starting/ending on a
 
You can add infinite legs to a junction. Each time you draw a segment starting/ending on a
  
 
junction object, a new leg is being added.
 
junction object, a new leg is being added.
  
Remodelling components
+
=== Remodelling Placeholders ===
 
 
48
 
 
 
Remodelling Placeholders
 
 
 
 
Existing MEP Placeholders can be remodeled in various ways.
 
Existing MEP Placeholders can be remodeled in various ways.
  
Line 960: Line 773:
 
can modify the vertexes of the path.
 
can modify the vertexes of the path.
  
Control points
+
==== Control points ====
 
 
 
Each placeholder contains exact 4 controlpoints. Two blue dots at the beginning and
 
Each placeholder contains exact 4 controlpoints. Two blue dots at the beginning and
  
Line 978: Line 790:
 
to another Placeholder, the dot will be indicated green.
 
to another Placeholder, the dot will be indicated green.
  
Remodelling Placeholders
+
== Working with fixtures ==
 
+
VectorMEP provides several fixtures for each discipline. While some fixtures have unique capabilities, they all work following the same logic.
49
 
  
Remodelling Placeholders
+
Fixtures require connectors in order to take part in MEP networks. Without any connectors, a fixture is nothing more then a symbol.
 
 
50
 
 
 
Working with fixtures
 
 
 
VectorMEP provides several fixtures for each discipline. While some fixtures have unique
 
 
 
capabilities, they all work following the same logic.
 
 
 
Fixtures require connectors in order to take part in MEP networks. Without any connectors, a
 
 
 
fixture is nothing more then a symbol.
 
  
 
The following fixtures are available:
 
The following fixtures are available:
  
Piping engineering
+
* Piping engineering
 
+
** Pipe accessory
Pipe accessory
+
** Plumbing fixture
 
+
** Mechanical equipment
Plumbing fixture
+
* Ducting engineering
 
+
** Duct accessory
Mechanical equipment
+
** Air terminal
 
+
** Mechanical equipment
Ducting engineering
+
* Electrical engineering
 
+
** Power fixtures
Duct accessory
+
** Electrical fixture
 
+
** Electrical device
Air terminal
+
** Lighting fixture
 
+
** Electrical switch
Mechanical equipment
+
** Junction box
 
+
** Data fixtures
Electrical engineering
+
** Data device
 
+
** Telephone device
Power fixtures
+
** Communication device
 
+
** Security device
Electrical fixture
+
** Fire alarm device
 
+
** Nurse call device
Electrical device
+
** Switch
 
+
** Panel boards
Lighting fixture
+
** Branch panel
 
+
** Switch board
Electrical switch
+
** Data panel
 
 
Junction box
 
 
 
Data fixtures
 
 
 
Data device
 
 
 
Telephone device
 
 
 
Communication device
 
 
 
Security device
 
 
 
Fire alarm device
 
 
 
Nurse call device
 
 
 
Switch
 
 
 
Panel boards
 
 
 
Branch panel
 
 
 
Switch board
 
 
 
Data panel
 
 
 
Customizing the symbol
 
 
 
Working with fixtures
 
 
 
51
 
  
 +
=== Customizing the symbol ===
 
Each fixture has at least one parameter controlling the used symbol.
 
Each fixture has at least one parameter controlling the used symbol.
  
Line 1,068: Line 836:
 
need to be displayed separately on a 2D-plan view.
 
need to be displayed separately on a 2D-plan view.
  
Reference levels
+
=== Reference levels ===
 
 
 
The electrical settings menu command offers custom story-alike settings named reference
 
The electrical settings menu command offers custom story-alike settings named reference
  
Line 1,080: Line 847:
 
the layer it is on.
 
the layer it is on.
  
Electrical panels
+
=== Electrical panels ===
 
 
 
Panel fixture types allow connections of circuits. The panel fixture itself can also be part of a
 
Panel fixture types allow connections of circuits. The panel fixture itself can also be part of a
  
Line 1,092: Line 858:
 
available circuits and panels in one overview.
 
available circuits and panels in one overview.
  
Load Classifications
+
=== Load Classifications ===
 
 
 
You can classify each type of electrical load connected to a panel. These classifications are
 
You can classify each type of electrical load connected to a panel. These classifications are
  
 
called load classification types.
 
called load classification types.
  
Demand factors
+
=== Demand factors ===
 
 
 
You use demand factors to adjust the rating of the main service for a building based on the
 
You use demand factors to adjust the rating of the main service for a building based on the
  
Line 1,106: Line 870:
 
full rated load.
 
full rated load.
  
Working with fixtures
+
== MEP Labeling ==
 
 
52
 
 
 
Working with fixtures
 
 
 
53
 
 
 
MEP Labeling
 
 
 
 
The MEP Label tool is capable of labeling/tagging all available MEP components.
 
The MEP Label tool is capable of labeling/tagging all available MEP components.
  
Line 1,130: Line 885:
 
irrigation tool set can also be used for tagging, which is far more superior.
 
irrigation tool set can also be used for tagging, which is far more superior.
  
Tool Modebar
+
=== Tool Modebar ===
 
 
 
1. Select component mode.
 
1. Select component mode.
  
 
2. Object properties.
 
2. Object properties.
  
OIP
+
=== OIP ===
 
 
 
Class
 
Class
  
Line 1,164: Line 917:
 
Edit symbol
 
Edit symbol
  
MEP Labeling
+
=== Customizing the MEP Label symbol ===
 
 
54
 
 
 
MEP Labeling
 
 
 
55
 
 
 
Customizing the MEP Label symbol
 
 
 
 
Clients can customize the MEP Label symbol.
 
Clients can customize the MEP Label symbol.
  
Line 1,184: Line 928:
 
in all your drawings, when the "Select Symbol" dialog is present.
 
in all your drawings, when the "Select Symbol" dialog is present.
  
Attached record with data
+
=== Attached record with data ===
 
 
 
Make sure the record "MEPLabel_Fields" is attached to the symbol. For those fields you
 
Make sure the record "MEPLabel_Fields" is attached to the symbol. For those fields you
  

Latest revision as of 07:07, 21 February 2021

File:VectorMEP User Manual.pdf
We are still converting our PDF manual to be included in this wiki. As long as you see this message and the reference above we advise to use the pdf instead of the content below.

IFC Comptability

All the available MEP components are able to be exported to the by Vectorworks supported IFC formats. Additionally, clients can alter the parameters of the attached IFC records. Some parameters will be overwritten by the object itself.

Contact us directly if you would like to have additional information transferred to the IFC tags by default.

IFC is an open standard, developed and maintained by buildingSMART International, for building data that permits information to be shared and maintained throughout the life cycle of the construction project: design, analysis, specification, fabrication, construction, and occupancy.

Global Settings

Using the "//MEP DISCIPLINE// - Settings" menu command, a dialog appears to manage global settings for that specific discipline.

Available disciplines:

  • Electrical
  • Piping
  • Ducting

Most settings are saved into the active drawing. If you are familiar with Vectorworks templates this is ideal to setup defaults for future projects.

General

Depending on the category, different common settings will be available.

Classification

Manage the classification system, create predefined family types to categorize and personalize your components.

Calculation

An overview of the available sizing and calculation methods. These methods can be extended by anyone using the SDK.

Materials

Manage available materials and dimensions. Dimensions are shown based on the active document unit settings.

Once a dimension is added to a material you can set it to be used as width and/or height by clicking the icons in the list browser.

Material settings are managed outside the document and are not part of a template.

Angles

Manage the available angles while using the MEP component tools.

Units

For some of our parameters, custom unit implementations are available. Our custom unit parameters fully support worksheets and the irrigation tag, translating the saved value to be displayed in the unit settings of your choice.

Both the Imperial and Metric unit system are supported.

Symbols

MEP components have an optional hybrid/2D view. These symbols will be displayed for each component type to indicate special cases in 2D plan view. (E.g drop, rise...)

Optional, you can set the symbol to rotate and scale:

  • Rotating: This will rotate the symbol into the direction on the XY plane.
  • Scaling: This will scale the symbol to match the component size. The scale will be calculated based on the pipe size versus the width of an 360°arc in the symbol definition. For best performance reasons you should put all the symbol contents into a group, except for the arc. The arc can be given an invisible pen and fill if you'd like to hide it.

Insulation

Manage insulation and lining predefined types.

Performance

Manage various settings with influence on performance:

Performance mode toggles the automatically recalculation of MEP system networks.

Support IFC export

Extrude 3D content

Segmentise "Straight Group Segments"

Straight Segment Groups will internally split into multiple Straight Segments based on

the material settings.

Assuming a Straight Segment Group with length 14 meter and a material dimension

with a max. length of 3 meter.

Internally there will be 5 segments.

Discipline specific settings

Fluids

Manage fluids by temperature, viscosity and density to be used when predefining family

types.

Underfloor heating

Manage reducing factors to be used with the underfloor heating object.

Load calculations

Manage common settings for electrical engineering, regarding power loads.

Classification

VectorMEP provides a classification system to categories MEP components.

Each discipline provides several hard-coded Families as base categories. However, for each

family available, it's possible to create unlimited family types, which are derived from the

parent family.

If your family type does not belong to any of the provided families, you can always use the

family "Other" to assign this custom family type.

Depending on the discipline and family, different setting appear while creating or editing a

family type.

Creating a family type

Family types can be managed in the Classification tab of the MEP settings dialog.

Piping

Electrical

Ducting

Assigning a family type

Each MEP component can be directly assigned to a family type, taking over the

predefined settings.

Connectors

Connectors are logical entities that are the missing link between a symbol/object and a MEP

component.

A connector is only valuable as part of an object.

We provide several fixtures for each discipline, that require the combination of connectors

and symbols to create smart responsive objects participating in MEP networks.

Choosing the right Connector

Different type of connectors are available depending on the discipline:

Pipe connectors are used for piping, pipe fittings, and other components that are

meant for transmitting fluids.

Duct connectors are associated with ductwork, duct fittings, and other elements that

are part of the air handling systems.

Electrical connectors are used for any type of electrical connection, including power,

telephone, fire alarm systems, and others.

CableCarrier connectors are used for any type of cablecarrier connection, including

power, telephone, fire alarm systems, and others.

Selecting the correct discipline is critical to the content working correctly. After this selection

is made, it cannot be changed without first deleting the connector and adding it again with

the correct discipline.

Choosing a family for a Connector

The base family type assigned to a connector determines the types of systems with which it

can interact and how it interacts with other system components.

Depending the discipline, different families are available as explained in the classification

article.

Adding connectors

You can add connectors using the following methods:

Using the Insert MEP connector menu command.

Connectors

26

This command requires an active selection of fixtures.

Using the correspondenting connector tool.

Connectors should only be added while being in the Connector group. Each fixture h

as a button on the OIP to enter this group.

Connector oriëntation

While selecting a connector, the direction is highlighted. The connector should always point

outside of the fixture.

Connectors

27

Connector types

Pipe connectors

Pipe connectors are used for piping, pipe fittings, and other components that are meant for

transmitting fluids.

The following list shows the different connector parameters, by property group and a brief

description of their functionality.

Preferences

Class

Description

Primary

Min. flow

Max. flow

Classification

Family

Mechanical

Flow configuration

Flow direction

Loss method

Loss coefficient

Pressure drop

Flow

Dimensions

Shape

Radius

Width

Height

Extrusion height

Duct connectors

Duct connectors are associated with ductwork, duct fittings, and other elements that are

part of the air handling systems.

Duct connectors contain the following parameters:

Preferences

Class

Description

Primary

Min. flow

Max. flow

Classification

Family

Mechanical

Flow configuration

Flow direction

Loss method

Loss coefficient

Pressure drop

Flow

Dimensions

Shape

Radius

Width

Height

Extrusion height

Electrical connectors

Electrical connectors are used for any type of electrical connection, including power,

telephone, fire alarm systems, and others.

Electrical connectors contain the following parameters:

Preferences

Class

Description

Primary

Classification

Family

Electrical

Apparent load ballance

Apparent load phase 1

Apparent load phase 2

Apparent load phase 3

Load category

Number of poles

Power factor

Voltage

Power factor state

Dimensions

Shape

Radius

Width

Height

Extrusion height

CableCarrier connectors

CableCarrier connectors are associated with CableCarriers, CableCarriers fittings, and

other elements that are part of CableCarrier systems.

CableCarriers connectors contain the following parameters:

Preferences

Class

Description

Primary

Classification

Family

Dimensions

Shape

Radius

Width

Height

Extrusion height

CableCarrier connectors

31

Managing systems

Use of systems

When fixtures have connectors assigned, it is possible to create logic groups of fixtures by

connecting the connectors.

For electrical engineering, systems can be seen as circuits, connecting devices together.

For mechanical engineering, systems are logic groups of components.

Creating systems

There are two ways of managing systems, by using the tools are menu available menu

commands.

When adding a device to a system, VectorMEP will search for a free connector matching the

family type of the system you are about to create. If it can't find a viable connector, a dialog

pops up to choose another specific connector.

Additionaly, when using the menu command to create a new system, a checkbox can be

used to activate the system manager tool as well.

Creating electrical systems

Creating piping systems

Creating ducting systems

Using the system manager tool

When using the system manager tool, you can select an existing system, or start with a new

one.

When a system is active, the containing objects are selected and highlighted in the drawing.

Use the specific mode bar option to add/remove elements to the active system.

When hovering objects, the highlighted color determines them being eligible.

Electrical systems can also be assigned to a panel directly using the tool.

Managing Insulation

MEP components can have insulation or lining attached.

Managing the addition of removal is done by the specific menu commands under the

VectorMEP ribbon.

Insulation ranges

When creating insulation/lining materials in the MEP settings dialogs, predefined ranges can

be supplied to set up default insulation sizes associated with MEP sizes.

In any MEP component, you can opt in for the dynamic insulation sizing based on the

material ranges. On any dimension change of the MEP component, the insulation thickness

will be verified based on the available ranges. If needed, the insulation thickness will be

updated accordingly.

Adding insulation/Lining

The dialog will suggest a thickness based on the available ranges. The specific range will be

highlighted in the listbrowser below.

Sizing and Calculation Methods

The "MEP Component sizing" menu command allows sizing of MEP components by

predefined methods.

Both these methods can be restricted for use with specific disciplines and/or families.

Calculation methods

Calculation methods calculate various factors, including the flow, velocity and pressure loss.

Calculation methods need be assigned to specific family types in order for them to be used.

Components based on a family type without a calculation method assigned will not make

any calculation.

Sizing methods

Sizing methods size MEP components based on the results of a calculation method, within

user defined boundaries.

If multiple sizing methods are available, and selected for use, it's possible to choose

between an AND or OR combination.

Depending on the discipline and family type, specific fluid settings are used in the

calculation.

You can apply constraints to limit the maximum height and width for the sections being

sized. When both the size constraints and the flow constraints cannot be matched, the size

constraints take priority, and an alert is displayed, indicating that not all of the sizing

parameters could be satisfied.

Custom methods

Both the sizing and calculation methods can be customized by adding additional implementations using our API.

Working with MEP components

Each discipline contains two tools to create rigid and flexible MEP components.

When using the rigid tool, fittings are automatically created depending on the situation you

create. This includes elbows, transitions and junctions.

Both the tools allow components to be drawn in all directions, including sloped parts.

Pipe Component tool

The "Pipe Component" tool draws pipework in a project.

Duct Component tool

The "Duct Component" tool draws ductwork in a project.

Cable Carrier Component

The "Cable Carrier Component" tool draws cable carries in a project.

Creating MEP components

Tool Modebar

1. Horizontal outline. (left, center, right)

2. Additional horizontal offset.

3. Vertical outline. (top, center, invert, bottom)

4. Additional vertical offset.

5. Slope.

6. Object properties.

Contextual menu

The right click contextual menu contains the following custom actions:

Select upwards: Selects the connected chain in upwards direction.

Select downwards: Selects the connected chain in downwards direction.

Reverse direction: Reverses the direction of the active component.

Divide slope: Evenly distribute the slope based on the first and last vertex height.

Apply slope: Applies a given slope.

OIP

Display

Class

UID

Profile rotation

Has cover

Attach tag

Constraints

Start offset

End offset

Slope

Top elevation

Bottom elevation

Classification

Type

Family

Family type

Section

Area

Dimensions

Material

Shape

Size

Nominal width

Lock width

Nominal Height

Lock height

Working with MEP Placeholders

Each discipline contains a tool to create placeholders. These are a simplified variation of

regular MEP components.

Placeholders do not contain any fittings and can be used to sketch a layout much more

quickly.

Pipe Placeholder tool

The "Pipe Component" tool draws pipework in a project.

Duct Placeholder tool

The "Duct Component" tool draws ductwork in a project.

Cable Carrier Placeholder

The "Cable Carrier Component" tool draws cable carries in a project.

Creating MEP Placeholders

Tool Modebar

1. Width/Diameter

2. Height

3. Vertical offset (used in 2D sketching)

4. Slope.

5. Object properties.

Contextual menu

The right click contextual menu contains the following custom actions:

Select upwards: Selects the connected chain in upwards direction.

Select downwards: Selects the connected chain in downwards direction.

Reverse direction: Reverses the direction of the active component.

Divide slope: Evenly distribute the slope based on the first and last vertex height.

Apply slope: Applies a given slope.

OIP

Display

Class

UID

Profile rotation

Has cover

Attach tag

Constraints

Start offset

End offset

Slope

Top elevation

Bottom elevation

Classification

Type

Family

Family type

Section

Area

Dimensions

Material

Shape

Size

Nominal width

Lock width

Nominal Height

Lock height

Remodelling components

Existing MEP components can be remodeled in various ways.

All conduit/duct/pipe based components are path based. With the native reshape tool you

can modify the vertexes of the path. While we don't disable this we do discourage this for

any component besides the Straight Segment (Group) and the Transition Segment.

Straight Segment (Group)

The OIP holds a parameter "Length". On setting a new value the segment will use the new

provided length.

Elbow Segments

The OIP holds a parameter "Radius". On setting a new value the segment will use the new

provided radius. The radius is the length of the first leg.

If the Object has adjacent connecting objects, this will only succeed if those objects can be

modified as well to match the new situation.

Modifying the angle

1. Select an elbow, click on the center CP (A).

2. Rotate the mouse to the desired angle. The toolbar displays the angle between the

legs.

3. Click to verify the new position.

Converting into a junction

1. Select an elbow, click on any outer CP (B).

2. Click on any outer CP (B) to switch between enabling legs.

Transition Segments

The OIP holds a parameter "Taper angle" and "Taper length". On setting a new value the

segment will use the new provided angle or length.

If the Object has adjacent connecting objects, this will only succeed if those objects can be

modified as well.

Horizontal shift

Each transition has 3 controlpoints to control a horizontal shift. From the OIP you can set an

additional vertical shift as well.

1. Select a transition, click on any CP (A).

2. Move the mouse to the desired location.

3. Click to verify the new position.

Junction Segments

The OIP holds a parameter "Radius". On setting a new value the segment will use the new

provided radius.

Removing junction legs

1. Select a junction.

2. Click on any outer CP (B) to remove and existing leg.

Adding junction legs

You can add infinite legs to a junction. Each time you draw a segment starting/ending on a

junction object, a new leg is being added.

Remodelling Placeholders

Existing MEP Placeholders can be remodeled in various ways.

All conduit/duct/pipe based components are path based. With the native reshape tool you

can modify the vertexes of the path.

Control points

Each placeholder contains exact 4 controlpoints. Two blue dots at the beginning and

endpoint of the segment, two additional controlpoints at distance from these points.

The blue controlpoints can be used to quickly reshape the placeholders.

The other controlpoints function likewise to the "create similar" command. The big difference

is that the tool will actually launch at the exact connectionspot, using it as a startpoint. This

makes drawing much faster and ensures a correct connection.

On default, these additional controlpoints have a red dot. Once they have a valid connection

to another Placeholder, the dot will be indicated green.

Working with fixtures

VectorMEP provides several fixtures for each discipline. While some fixtures have unique capabilities, they all work following the same logic.

Fixtures require connectors in order to take part in MEP networks. Without any connectors, a fixture is nothing more then a symbol.

The following fixtures are available:

  • Piping engineering
    • Pipe accessory
    • Plumbing fixture
    • Mechanical equipment
  • Ducting engineering
    • Duct accessory
    • Air terminal
    • Mechanical equipment
  • Electrical engineering
    • Power fixtures
    • Electrical fixture
    • Electrical device
    • Lighting fixture
    • Electrical switch
    • Junction box
    • Data fixtures
    • Data device
    • Telephone device
    • Communication device
    • Security device
    • Fire alarm device
    • Nurse call device
    • Switch
    • Panel boards
    • Branch panel
    • Switch board
    • Data panel

Customizing the symbol

Each fixture has at least one parameter controlling the used symbol.

Electrical fixtures have a primary and secondary symbol for a specific purpose:

The secondary symbol can have a horizontal shift and rotation versus the insertion poi

nt. This can be of use when electrical fixtures are stacked on top of each other, but

need to be displayed separately on a 2D-plan view.

Reference levels

The electrical settings menu command offers custom story-alike settings named reference

levels, which are predefined relative heights.

When vertically aligning fixtures, it's common to have default installation heights of

components. Reference levels can be applied to add a relative height to an object, no matter

the layer it is on.

Electrical panels

Panel fixture types allow connections of circuits. The panel fixture itself can also be part of a

circuit, connected to another panel.

Panels require a valid distribution system before they can be used with circuits.

The Organisation - Electrical panels menu command manages the relations between all

available circuits and panels in one overview.

Load Classifications

You can classify each type of electrical load connected to a panel. These classifications are

called load classification types.

Demand factors

You use demand factors to adjust the rating of the main service for a building based on the

expectation that at any given time, not all of the electrical equipment will be drawing at the

full rated load.

MEP Labeling

The MEP Label tool is capable of labeling/tagging all available MEP components.

The object is symbol based and uses a predefined record to transfer data into the symbol.

Clients can customize this symbol and choose which fields to show.

The MEP Label will automatically position itself vertically on top of the bounding cube. This

ensures it is always visible from the top view.

If you have the Vectorworks designer of landmark installed, the tag label from the

irrigation tool set can also be used for tagging, which is far more superior.

Tool Modebar

1. Select component mode.

2. Object properties.

OIP

Class

Dimension text: Switches between the nominal size and the size based on the

document settings.

Show leader: Shows a leader line to the middle of the referenced object.

Overwrite defaults: Leave blank to use defaults.

Prefix

Separator

Suffix

Label symbol

Symbol

Scale

Select symbol

Edit symbol

Customizing the MEP Label symbol

Clients can customize the MEP Label symbol.

Best practice is to duplicate one of the default symbols and to modify it to your needs. Each

MEP Label can select a different symbol for different situations.

If the custom symbols are added to the MEP Label symbol library they will become available

in all your drawings, when the "Select Symbol" dialog is present.

Attached record with data

Make sure the record "MEPLabel_Fields" is attached to the symbol. For those fields you

would like to display, link the appropriate record field to a text field inside the symbol.

This makes sure the data is correctly transferred.

The size fields can hold the nominal material size OR the size based on the document unit

settings.